Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

potterton suprima?

i have replaced the p c board = thermistor = o/heat stat work ok for 3 weeks now wont ignite
HARRY FRANZMANN, July 2008
you have a great boiler apart from a dodgy pcb problem, so you have changed the pcb for the up graded version, which includes the rewire of the whole boiler electric's. and it worked ok for a few weeks ,so you must have done a good job. Ok. the new board has its own diagnosic light , the new board kit came with a manual, read this and see if the flashing light tells you what is wrong. If the indication light said that there is no demand then its the external switches not giving you a switched live back. Also did you change all the wires that were sent with the PCB kit in perticluar the spark electrode wire.

andy the gas man, July 2008
need more info, where in the ignition sequence does it stop? fan runs? electrodes spark? gas valve energises?

T, July 2008