3 hours ago Karen asked ... Royal 480nt cash register?    |    andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    Click here to ask your question

boiler pipework?

What are the 4 pipes from the potterton flamingo 50 boiler. Two are 22mm, I assume they are for the c.h and dhw, the other two are 28mm. Are they the expansion and cold water fill from the roof tank?
I want to take the boiler out and in so doing want to maintain the cold water supply to the house.
kenith, July 2008
if there are four pipes + gas supply from the boiler, then the 2 x 22mm pipes will be for the pumped central heating (flow+return) and the 2 x 28mm pipes are for gravity feed hot water (usually)