Jo asked ... How to engage clutch on old sewing machine to engage needle?    |    Jacky asked ... Miele Vacuum cleaner?    |    Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Click here to ask your question

how can i fix my baxi 105e combi boiler?

It will not ignite and the red flshing light is on the 50 degree mark. Help! Am cold and dirty!
Lucy, August 2008
The 50 degree light flashing shows that there is a fault on the fan or flue. i have always found that if it isnt the flue that has parted(vertical flue usually) than the air pressure switch will need replacing. I come across this fault alot at work and i garantee that this part will solve your problem.
I wouldnt recomend changing the p.c.b before replacing the a.p.s

lee, eastyork, September 2008
Sounds like relay on pcb isnt working prop, replace pcb baxi have made a new upgrade pcb for the 105 boiler

Baximan, September 2008
This is most likely to be fan or fan pressure switch. The flashing light at 50 degrees points us to these. Could be other things but these are most likely. If you can hear the fan running but boiler doesn't light then I'd almost certainly say it's the FPS. Have changed these in the past on these boilers but never a fan yet.

Rob, Derby, August 2008
link Click here to see other fixes for Baxi 105E.