Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Click here to ask your question

38CXI F14 fault?

When i run my hot water tap water is slightly warm and my radiators start getting warm.An F14 fault appears and i have changed thermistor like it saids in manual but i still have same problem. Can anyone shed any light please.
Andy, August 2008
Hi, Sounds very much like the diverter valve is passing, or the diverter valve motor isn't motoring over fully. try removing the motor and running the hot tap, see if the motor moves fully over, if it does, then it will be the valve, if it doesn't then it will be the motor. I'm pretty sure removing the motor is just a click and a twist, no water will come out so you should be ok on that score.
(I book mark all the pages I post answers on, so let me know how you get on.)

LTGF, August 2008