Jo asked ... How to engage clutch on old sewing machine to engage needle?    |    Jacky asked ... Miele Vacuum cleaner?    |    Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Click here to ask your question

baxi 105e too much pressure?

my boiler baxi 105e sits at 1.5 bar no problem but when asked for ch pressure goes up and it blows off at 2.5bar whats causing this
pawbroon, September 2008
most common problem, expansion vessel flat or dead. 95% chance its dead.

options are to recharge it if its ok but flat or
1: replace like for like vessel in boiler
2: fit remote vessel to ch system somewhere hidden.

iain, September 2008