Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Click here to ask your question

Worcester Greenstar CDi Error Message?

How do I remove the error message SE from my boiler having had a recent service?
Brian, October 2008
OK:

Press spanner button for 10 sec til lights up orange

It will say 1.a in the display

Press "eco" repeatedly til this says 5a

Press chimney sweep (man with ladder) button once, it will light up

You should see 00 in display

Press "eco" once, won't do anything but press anyway

Now press and hold chimney sweep til you see [] in display.

When you see [] let go.

It will go back to 5a.

Now press spanner once to get back to normal mode.

Voila :)

BunSlinger, October 2008
The SE error appears after 2340hrs burner operation, It is not a fault code and does no harm. Whils it can be reset the procedure is a bit long winded. I would suggest that when you have it serviced next you get the engineer to reset.

Mike, October 2008
link Click here to see other fixes for Worcester Greenstar.