Cass asked ... Replacing full bulb housing unit in Neff oven?    |    Pádraig O Sabhain asked ... How to fix Kenwood Slimline Dishwasher KDW45X20 with a F1 Er?    |    keith asked ... How to reset after battery change?    |    Carol asked ... How to remove roller from lawnmower?    |    Ariana Orellana asked ... Code?    |    Click here to ask your question

creda 1000 problem door jam?

the door on my creda 1000 simplicity series wont open ,how can i open it?
peter, October 2008
I don't have an answer to this, I have the same problem. How did you sort it out

Dave, June 2009
Switch power off. Some interlocks prevent the door from opening if the drum is moving. The mechanism that detects this is called a pecker unit and it is located around the motor pulley. It connects to the interlock via a cable assembly. If the pecker unit is broken in the "on" position it may be preventing the interlock opening. Visually check and try to activate the mechanism by hand.
Other interlocks have a secondary locking system which ties in with the pressure switch - the mechanism which detects if there is water present in the drum. If this system is faulty - caused by blockages in the filter, pressure vessel or the thin rubber pipe running to the pressure switch the machine "thinks" its still full of water and wont allow the door to be opened. Take off the top cover, examine the interlock from behind and detach any rubber pipes or cables to try to open it from inside. If all else fails, the interlock itself may be faulty and will have to be broken open. A replacement interlock unit and/or catch will of course be required.
Check out www.2ndwave.co.uk/manual.html

dannyboy, October 2008
link Click here to see other fixes for Creda.