Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Click here to ask your question

Heating boiler through the programmer is on hot water ok no heating to rad?

Boiler operates in the hotwater mode, put the switch over to the heating,no heating,room stat on max, 3 port valve with lever loose and energised, only way at this moment to get heat is put the temp up on cylinder stat and leave heating switch in heating mode and heating circulates while hotwater reaches temp and goes off until hotwater used....is there any help out there.
neil, October 2008
Faulty synchron motor in diverter valve, motor not travelling as far as microswitch so pump and boiler not firing. Screwfix sell universal synchron motors think they're about £15.

meheatandplumb@aol.com, October 2008