Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

no heating or hot water?

ive no heating or hot water.the boiler isnt coming on at all.theres no pressure.the make is a ferroli combi.modena 80 e.
andrew hunter, October 2008
The pressure needs to between 1-1.5 bar on your gauge,you need to bring that pressure back up by opening the filling loop on the pipework under the boiler,what that doe's is fills the heating system back up with water which will bring the pressure back up on your gauge.When you have done that you then need to vent your radiators of any air then check the pressure on the gauge and bring back up if need be.

herbie, October 2008