Andrew - C asked ... Stannah 400?    |    Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    Click here to ask your question

Glow-worm 30CxI?

i have a Glow-worm 30CxI combi boiler and i need to drain the system could you give me any help thx
karl, October 2008
Amateur advice, so beware.

Do not be tempted to use the pressure relief valve to drain the boiler; you may get debris in the valve which will cause problems.

The way I have done this in the past is to turn off the electrical power, let the system cool and then drain boiler, radiators and all by using the drain cock of the heating system, usually to be found at the lowest point. Failing that, use the lowest radiator's bleed valve.

When you come to refill the system, use the built-in filling loop (blue knob underneath the boiler), and use it carefully: people say that it's a bit fragile. Pressurise to 1.0 bar.

Jonathan, October 2008
please contact : technical@glow-worm.co.uk

andy, October 2008
link Click here to see other fixes for Glow-Worm.