Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Suzie asked ... Stuck Feed dog?    |    Click here to ask your question

fan on light ?

I have the fan only light on on my baxi solo 30/80 boiler i have no heating ?? Any ideas whay has happened ?
paul Quantrill, October 2008
If the fan is running then it could be the air pressure switch at fault, When the fan operates the APS senses the movement and the PCB moves on tho the next stage of ignition (pilot & ignition spark)
The tubes to the APS can get blocked or broken which will result in it staying in the fan only mode.
Good luck, hope this helped.

Martin, October 2008