Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Click here to ask your question

Baxi 80 ech does not heat up the CH?

Hi , I wonder if you can help we have a baxi that keeps the water hot but will not heat the CH, it keeps firing, makes like s fizzling noise then 30 seconds later it cuts out. We have had the pump replaced as before it was warming up the upstairs radiators but not the downstairs ones. Any Idea's cause its costing me an arm and a leg to get sorted
Mo, November 2008
If the pump is running then there can be a few problems.Check the pressure on the boiler to start and bleed the rads. make sure the lock shealds are turned on and the trvs.
does the boiler fire up then you turn the heating temp up on the boiler front if not check the diverter valve! are the pins working?? they should open and close on the CH and the DHW when turned on.
Check the pipe work for cross over or blockage from dirt or old age.

How old is the boiler as it may need changing.

good luck.

mick

mick brown, November 2008