narnia asked ... Matsui ct-111ss?    |    Jason asked ... How to fix handset problems ( intercom ) and access control?    |    andy asked ... Samsung VP-D60 camcorder?    |    Shopper asked ... Poor Renault Radio Reception?    |    reg bardle asked ... Lg 7kg dd?    |    Click here to ask your question

Vokera compact 28 bar pressure keeps rising ?

Ive disconected the fill loop yet the presure keeps rising so I turned off the stop cock for the hot water supply underneath heater and the pressure stays the same is it the heat exchanger or the expansion tank
David Johnson, November 2008
if pressure rises with appliance turned off (ie not heating) then you'll be looking at heat exchanger. compact is dual pass main exchanger so cold mains is entering system side somewhere.

expansion vessel would be stable pressure then would rise from say 1 - 3 bar after about 10 mins of having heating on

iain, November 2008