andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

HOW MUCH AIR TO PUT IN EXPANSION VESSEL? POWERMAX BOILER?

I have a Powermax 155 Combi which loses pressure a lot. Ive heard that if you pump up the expansion vessel then this might stop the loss - but how much air do I put in?
Mike, November 2008
Before you do that check for water in ex vessel tyre valve if you have then get a new one.

daz71, November 2008
Doubt if its the ex vessel. But if you really want to, use a tyre pump. pressure approx 0.5-1 bar. make sure you have depressurized ch system first and leave drain cock open to allow the water to escape when pressurizing vessel.

daz71, November 2008