Carol asked ... How to remove roller from lawnmower?    |    Ariana Orellana asked ... Code?    |    Lynnie asked ... BT Studio 4500 cordless telephone?    |    David Dawes asked ... How to recoil the starter spring - Champion R484TR?    |    peter high asked ... How can I set time on my Neff oven?    |    Click here to ask your question

worcester bosch gas boiler 28si ll?

pressure gauge on zero bar, how do i bleed system?
mr a higgins, November 2008
how do i change the turbine spinning flow switch on my worcester 28si ll boiler

keith, March 2013
If its on 0 bar then you have lost pressure for some reason i.e. leak or faulty pressure relief valve or maybe even a pressure gauge fault. Try repressurizing system using filling loop(with c/heating off) fill to 1.5 bar then go round and bleed air out of top of radiators then go back and fill again to 1.5 bar and so on until all the air is out. Check your pressure relief pipe if water is coming out then you need a new pressure relief valve (the pipe is on the xternal wall other side of boiler).

daz71, November 2008