38 mins ago Chris. asked ... Miele W800 novotronic washing machine?    |    Larry asked ... How to stop my steam iron from leaking. Model dw2463 Rowenta?    |    HT asked ... Radio code Philips 22RC200/35?    |    Roberta asked ... DW5080?    |    Dave asked ... Toilet Push Button not flushing properly?    |    Click here to ask your question

worcester 280 rsf thermostatic reset button?

thermostatic reset button keeps popping out after one hour of running can not keep radiators hot can you help source fault
ady christian, November 2008
chances are if the overheat stat is popping out there's a reason for it and that is because the boiler is over heating ! this is probably due to bad circulation so either the system is sludged up and neeeds cleaning or the pump in boiler is weak or both, the first thing to try is to add some strong cleaner to system like sentinal x400 or fernox etc and run boiler with this in the system for a while (or until boiler cuts out ! ) drain and then add sentinal x300 and leave that in there for a few days (at this point the boiler should keep running) drain and then add sentinal x100 inhibitor and leave this in there. the only other alternative is a power flush b ut these are expensive and dont always work and you wont find out till you've parted with £300/£500 so try the DIY method first and at least then you've only lost £40 ! ooh and dont forget to vent all air in between each operation....