Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Click here to ask your question

POTTERTON PUMA COMBI?

WAS HAVING LOW PRESSURE WARNING LIGHT ON, SO HAVE REPLACED WATER PRESSURE SWITCH, NOW GOT HOT WATER, BUT HEATING ONLY LASTS FOR APROX 1 MIN THEN THE BOILER SHUTS DOWN AND LOW PRESSURE LIGHT COMES BACK ON. I HAVE DRAINED THE BOILER THEN TOOK THE SWITCH THEN PUT IT ALL BACK TOGETHER AGAIN, JUST IN CASE I DID SOMETHING WRONG THE FIRST TIME,
REFILLED THE SYSTEM THEN FIRED THE BOILER BACK UP AND THE SAME HAPPEND... HOT WATER OK HEATING APROX 1 MIN...
SO HELP PLEASE...
WINCY..., November 2008
Potterton puma 80 combi, pilot light goes out after a while, changed pilot light assembly because existing perorated

John.L, December 2008
Spot on... Bled the pump. We have heat again.

Thanks

wincy, November 2008
it could be air locked or blocked also can you tell if pump is working

arthur, November 2008