Andrew - C asked ... Stannah 400?    |    Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    Click here to ask your question

is my chaffeteaux celtic combi boiler past it?

my boiler has given 20 years of pretty good service but recently central heating is working OK but hot water cuts off when running a bath or shower then comes on again after 5-10 mins or so. Live in a high limescale area too.
Colin, December 2008
The secondary heat exchanger's primary water ways are partially bloked with sludge (limescale will only slow water flow) it would be expensive to clear and there are no guarantees it would work. You could try adding sentinel x300 to the boilers primary curcuit and running it for 30mins-1 hour (read x300 instructions on bottle).

Ray, January 2009