Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Click here to ask your question

How do I refill/top up a Baxi Combi Boiler?

The pressure on my Baxi Combi aprox 0.1 and I know it needs to be topped up but I havent a clue which tap needs to be opened. I hope some one can help me!! Thanks
Shiver, December 2008
There should be a "Filling Loop" on the pipework below the boiler, it is a silver braided metal hose with a quarter turn valve at one, or sometimes both, ends. The valve will have a black or blue handle to turn it on. If it has two valves, open one fully, and the other slowly until your pressure gauge starts to move up, shutting the valve(s) when the needle reaches 1.5 bar.

scott, December 2008