Dwayne B. asked ... Intermittent (twice) Then Complete Loss of Power?    |    Aunt Bee asked ... Bernina Update 1630 work light not working?    |    Larry asked ... Hybrid Weed wacker not working with battery?    |    Dan asked ... Why is Google Keep so slow on my iPhone?    |    dave s asked ... Transmission not working?    |    Click here to ask your question

pressure too high ?

my ariston boiler goes too 3 bar from 1 bar idle
rj, December 2008
either the filling loop is passing or the heat exchanger is split, also look at the expansion vessel check it is pressurised.

richofix, January 2009
expansion vessel is either depleted of air or its hole'd...drain boiler check air charge in vessel with foot pump (should be round 1 bar) if its empty then pump to 1 bar

mark the gay boiler man, December 2008