Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

pressure too high ?

my ariston boiler goes too 3 bar from 1 bar idle
rj, December 2008
either the filling loop is passing or the heat exchanger is split, also look at the expansion vessel check it is pressurised.

richofix, January 2009
expansion vessel is either depleted of air or its hole'd...drain boiler check air charge in vessel with foot pump (should be round 1 bar) if its empty then pump to 1 bar

mark the gay boiler man, December 2008