GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

potterton profile 80 wont fire up?

my potterton profile 80 wont fire up the thermostate is up the boiler stat is on max the fan is running
robin, December 2008
Call for heat (programmer + thermostat) Fan Runs
Pressure Switch senses fan running and
Pliot light Lights
PCB senses pilot light burning and
Main Gas Valve Opens

The back of the Manual has a fault finding chart.

People say the Printed Circuit Board suffers dry joints and sometimes they're right but not always. You can take the bottom cover off the boiler (one screw under a flap at the bottom) and tap the PCB and other parts with the handle of a wooden spoon to check for bad connections.

If the pilot fails to light suspect the pressure switch.

Make sure the over temp stat has not popped - button reset hole underneath. May have popped because temperature control set too high. Put it on 3 or 4 - not max.

Peccavi, December 2008
no the piolet light wont light

robin, December 2008
Robin,

Is the pilot light alight?

Strangely another Robin has exactly the same prolem as you do!

Peccavi, December 2008
link Click here to see other fixes for Potterton.