Toddy asked ... Pdw5048tms saw?    |    Karen asked ... Royal 480nt cash register?    |    andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    Click here to ask your question

potterton prima f central heating won't switch off?

I've replaced the control unit and the problem persists.
Hot water responds to timer etc but central heating stays on constantly and has to be controlled by the thermostat or isolated altogether at the mains.
The PCB is less than 2 years old ...Has this gone again?
Ray King, December 2008
Boiler is operating as it should,you have a system fault
Check programmer room stat and diverter valve
Check if you have a frost stat if calling it will override system control

a, December 2008
link Click here to see other fixes for Potterton Prima F.