55 mins ago Kathy asked ... Samsung ER-4915?    |    Mark asked ... Oven door removal?    |    Jt asked ... Where to buy mt270x petrol cap?    |    Jo asked ... How to engage clutch on old sewing machine to engage needle?    |    Jacky asked ... Miele Vacuum cleaner?    |    Click here to ask your question

what should i do?

i have a worcester 24i RSLF combi boiler and its reading that there is no bar pressure at all.
steph, January 2009
The boiler needs refilling.Look under the boiler and you should see a filling loop.Connect this to the pipe and switch the water valve on watching the gauge as it fills.Let it get to 1 bar,then turn off the water valve and disconnect the pipe.Do not let it get to 3 bar as the boiler has a safety valve which will blow off if you go above that level.

Tony S, January 2009