Alan asked ... Problem with JCB 3CX transmission?    |    Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Click here to ask your question

Baxi Combi boiler 105e - No pressure ?

Pressure gauge showing as "0". When turning temp to over half way boiler becomes noisy and sounds as if it is struggling so I have to turn it down again. Radiators have all been bled but are not as hot as they usually are.
Carly, January 2009
Hi, having the same problem but can't see the intake fill pipe anywhere ...... Where might it be? Please help

Ade, October 2010
hi is it an easy task fitting pressure reliefe valve

lee searle, May 2010
My Baxi Combi 105e is reading a pressure reading of '0', all seems to be working fine and I have hot heating and heating. all the lights between 6 and 11 are on constantly, I am assuming this is normal.

Do I need to bleed the radiators, I don't know, looking for any advice I can be given.

Regards

Bobby

Bobby, June 2009
i have a baxi boiler and i have been told that it is on a "continous fill system" does that mean u do not have to bleed and add more water to system to bring back pressure? IF so i cannot see an inlet tap to boiler

Vicki Cook, February 2009
You will need to bring the pressure back up on the guage by turning on the tap on the flexible filing loop until the guage reads one bar. Each time you bleed the radiators, you willl have repeat this process. You may also have a slow leak in the system? keep an eye on the pressure and see how long it takes to go down.
Sometimes the pressure relief valve on the boiler leaks,you will know if this is happening by looking at the small copper pipe outside. if there is some water coming from this pipe - the relief valve will also need to be replaced.

SPS, January 2009
link Click here to see other fixes for Baxi 105E.