GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

How can I restore water pressure in my Vokera Linea 24/28?

My pressure guage has dropped below 1bar, just above the first red line. How do I restore the pressure to normal level and when is the best time to it?
Should I turn the boiler off first?

I have also noticed that 3 of my radiators are not getting fully warm....is this conected to my boiler problem?
Alexandra, January 2009
call a plumber

best answer, May 2010
If you have an instruction manual read it - if not, these comments are generic to pressurised system. Somewhere in or very near your boiler (usually just under the boiler casing) you will find a 'filling loop' this will connect cold water mains pressure water to your sealed pressurised system. On some boilers the loop is permanent and you simply turn a key/valve/tap in order to increase pressure. On other systems you have to connect a braided steel flexi hose to two outlets one mains and the other heating. Once the loop is screwed on to both 'taps' you can open both valves until the presure is correct.
Make sure the system has cooled down before you do this. After you have restored the system pressure to its correct level you can bleed any radiators you want to remove air - but remember this will have the effect of lowering the system pressure so you may have to top up again (depending on how much air you bleed off). Hope that all makes sense!

Richard, January 2009
link Click here to see other fixes for Vokera.