49 mins ago Ela asked ... Worcester 30 Cadillac combi boiler won’t fire up and the EA?    |    Alan asked ... Problem with JCB 3CX transmission?    |    Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    Click here to ask your question

How do i fix my worcester bosch 30cdi combi boiler?

Had new boiler installed 4mnths ago and today it started making strange noises. (pressure display within the blue marker) A few minutes later "EA" flased on the display. Turned off and restarted with no joy- boiler starts to reheat but the same happens. Any advice as to what to do next. What does "EA" mean?
Derry, January 2009
I have exactley the same problem. Solution pour hot not boiling water on the condensing pipe - the pipe outside leading into the ground.

Umesh, January 2011
Boiler condensate pipe is blocked or frozen the gurgling sound is I sign of this

Dazzer, January 2009
flame not detected!!!
Is gas cock turned on?Check gas supply pressure,power supply, igniter electrode and lead, ionisation sensing electrode and lead, flue duct and CO2 level

sylwia, January 2009
link Click here to see other fixes for Worcester.