GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

Boiler problem - Myson Apollo 50s?

My boiler has stopped heating and my engineer is stumped. I have a small baby and need the heating on asap (though it's not worked now for a week despite daily visits by my engineer).

Pilot light stays on ok
After being left for a few hours the main gas can be switched on but will cut off after 2 minutes and can't be restarted.
High and Low stats were changed - no effect
Overheat sensor not changed but engineer says it can't be that otherwise it would cut the pilot light too.
There is 240v going to the gas valve.
Pump seems to be working as when it does heat for 2 mins, hot water is getting circulated.
If a gas valve solanoid is knackered would it exhibit these symptoms?

Cheers
Steve Jones, January 2009
I had the same problem with my 20 year old Apollo 50 .It was the first time it had failed , so not doing too badly .

Changed the gas valve solenoid coil and all was well in my case . Worth a try !

Richard Barker, April 2010
If there is 240v at the gasvalve and the mainflame isnt on then it has to be the gasvalve if the pilot is lit.So yes the solenoid appears faulty.

Tony S, January 2009
No real knowledge of boilers but your fault fascinates me...

The problem seems to be connected with the main gas valve - reluctant to open and shuts off too soon.

Either you have two faults - (1) slow to open and (2) closes before it should - or you have one fault that is causing both of these symptoms....

Your statement "the main gas can be switched on" confuses me slightly. I guess you mean the boiler itself switches on the gas valve rather than a person doing it.

I suspect you have just one fault but that's mainly a guess in the hope for your pocket and a quicker solution.

If the solenoid valve were "sticky" it may explain a reluctance to open, as would an issue with failing to sense the correct pilot light operation - you do have a healthy pilot flame I suppose. But neither of these would explain the other symptom of shutting down prematurely.

A poor connection in the circuit that controls the main gas valve could explain both fault conditions. This might be in the wiring, wiring connector blocks, the solenoid itself or the control board.

Wiring is relatively easy to check - tapping and wriggling.

The solenoid itself more difficult and costly so this is best left until last.

Many people suspect the control PCB in boilers and quite a few suffer from poor joints - a poor joint on your circuit board may explain the fault and would be relatively easy to detect and repair.

If you are tempted to take it out for inspection take a digital camera picture of the wiring to give you confidence in putting it back.


Good luck... Apologies for such a long reply from an unqualified person...

Peccavi, January 2009