Hi there,
Used the dip switch method which diagnosed PCB 2 as the problem.
I had replaced this board 2 years previously and doubted it was the problem.
I then found this thread and checked the fan at the top of the boiler and found it to be turning but a bit stiff so I was about to take everything apart when it loosened.
I had only taken out the earth wire screw, which released a small nut which was a bugger to get back into place but eventually I managed it, when the fan suddenly loosened, probably no connection but due to fiddling about in the general area.
Once everything was back together the boiler switched on and now works a treat.
Stevie R, October 2009