Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Suzie asked ... Stuck Feed dog?    |    Click here to ask your question

I replaced my pump now I have no hot water or heating?

I had to change my pump so I swtiched off all the water and drained the system. I could not find the fill loop valve so I jsut turned off the water at the mains. I have refilled my system and bled all the rads but now my boiler only comes on for a minute then shuts down. someone has suggested there might be a blockage in the cold water suppy to the boiler? How do I check this?
Mr john Kennedy, February 2009
it sounds to me as though the pump is not circulating, vent the pump through the screw at the front. and vent all rads and bleed taps any where on system untill it is working. some times its better to let things settle 1st for a night or so then bleed everything again untill its working. if the rads/system/ boiler are full then its not a blocked cold feed. sometimes the boiler can get airlocked depending on its position.hope this helps. you may have to drain and refill

john, February 2009
sounds to me like you have got an air lock in your system.try and get any air out of the pipework especially where it may rise. if you take a radiator off making sure you have turned the valves off and open a rad valve into a bucket and try and pull it thru .