GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

thorn apollo boiler?

heating goes off after 2 hours pilot light still on
then heating comes back on 1-2 hours later
is it the thermocouple
paul, February 2009
IF HEATING (RADIATORS) ARE OFF BUT HOT WATER IS ON AND SOME RADIATORS ARE STILL HEATING UP I WOULD SUGGEST YOU LOOK INTO CHANGING THE CENTRAL HEATING MOTORIZED VALVE IF YOU HAVE ONE

GC, October 2009
I have a thorn apollo 30/50 an the pilot light is the only thing thats working,about three weeks a pop came from inside i took a look and the surpresser had blown.this as been replaced but still not firing up any ideas

Richard., September 2009
I HAVE A 1987 THORN APOLLO BOILER . WHEN I SWITCH FROM CENTRAL HEATING TO JUST HOT WATER ON THE BOILER SWITCH RADIATORS ARE STILL ON. I HAVE CHANGED THE SWITCH IT IS STILL THE SAME. WORKED FINE LAST YEAR. ANY IDEAS DOES SOMETHING ELSE NEED CHANGING. I HAVE ALL THE MANUALS FOR THE BOILER AND HAVE CHECKED CONTINUITY ON ALL WIRING AS I AM AN ELECTRONIC ENGINEER, HAVE NOT CHECKED THERMOSTATS.

MR MARTIN SMITH, June 2009
try the thermo i have just re-newd my thermo cost was £12 the heating ect was ok after changing it
(reason for changing it was the heating /hot water was going off after about 1/2 hour )
hope this helps

vincent, March 2009
If pilot light stays on than thermocouple is intact. could be overheat stat on heatexchanger if manual reset not required. or gas valve, you need expert to find fault when boiler cuts out to pinpoint exact fault.

Mr. K., February 2009
No,its only the thermocouple if the pilot goes out and fails to relight.Could be the room stat if you have one.

Tony S, February 2009
link Click here to see other fixes for Thorn.