start with checking the elements for short to earth, then check the wash motor for the same. if you dont have testing tools (multimeter or ideally insulation tester) then try the old method of disconnecting the items live supply. if the trip doesnt blow after disconnecting one or the other then that is your fault
tony, February 2009