first thing you must do remove the cover then at far right you should see the lamp holder get the screws off replace lamp it's important to put some tape on the lamp and lamp holder . If you don't it will unscrew itself with the vibration of the magnetron. It is important not to touch the capacitor it will give you an electric shock even unplugged.
mc gyver, March 2009