Toddy asked ... Pdw5048tms saw?    |    Karen asked ... Royal 480nt cash register?    |    andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    Click here to ask your question

my perfecta 24 powers up extract fan motor runs but no ignition?

when boiler is switched on the boiler cycles you can here the fan motor start up but boiler fails to light (no ignition) have checked all the micro switches, the thermistor, ohms vary in hot and cold water, checked
the thermal cut out,checked ignition coil ohms value, checked ohms value on valve coils, changed the pcb, and selector switch, can a water pressure have a bearing as the highest BAR is just over 2.2bar can't get it up to 3bar.
R.Douglas, February 2009
check the aps , and tubes , any slight blockage stops switching

Ciaran, February 2009
link Click here to see other fixes for Perfecta 24.