2 hours ago Guy asked ... Gaggenau fridge alarm problem?    |    mike asked ... Fisher & Paykel 913t dishwasher?    |    Emma asked ... Foot pedal smoking?    |    Morne asked ... My defy dtl 125 toploader?    |    Ernie asked ... How to fix gearchange ldv maxus van 2006?    |    Click here to ask your question

while running hot water boiler runs hot & cold for the duration tap is on?

tested gas supply 21 mb flow rate 12 ltr removed heat exchanger dhw clear changed both ch &dhw sensors checked dhw pump & control board by substitution what to look for next ?boiler worcester 35cdi combi about 9 years old
les, March 2009
replace the heat exchanger,clean the system had the same proplem before xmas it is the heat exchanger

stew, March 2009