Mike asked ... Bosch WTA74200GB Vented Dryer?    |    Stuart G asked ... C3 Front Wiper control problem?    |    Clare S asked ... Repair Electriq dehumidifier?    |    Bob asked ... Charger fault?    |    Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Click here to ask your question

any advice or tips on fitting a valliant diverter valve part 011289?

Hi just ordered a diverter valve for my valliant boiler any tips or advice?
jim webb, March 2009
Its not that hard >>>>>>>>>>>ish
7.15 Replacement of diverter
valve
• Turn off boiler as in section 7.1.1.
• Remove front casing as in section
7.1.3.
• Release CH water pressure and
drain boiler as in section 7.1.2.
Open hot water taps.
• Lower front control panel as in
section 7.1.6.
• Remove pump as in 7.12
• Remove three screws (1, fig. 70)
and pump support bracket (2, fig.
70).
• Remove clip and disconnect pressure
tube (1, fig. 71) from diverter valve.
• Undo nut (2, fig. 71) and
disconnect pressure guage tube.
• Disconnect union (6, fig. 71).
• Disconnect electrical connections
from DHW microswitch (3, fig 71).
• Remove clip (4, fig. 71) by pulling
down.
• Undo two unions (5, fig. 71).
• Undo union (3, fig. 72).
• Carefully pull diverter valve and
cold water inlet pipe away from
DHW heat exchanger Lift valve and
cold water inlet pipe (1, fig. 72)
out of boiler.
• Reassemble in reverse order.
• Carry out electrical checks (see
section 5.1).
• Refill and repressurise the boiler
(see section 5.4).

justeve, March 2009