Mike asked ... Bosch WTA74200GB Vented Dryer?    |    Stuart G asked ... C3 Front Wiper control problem?    |    Clare S asked ... Repair Electriq dehumidifier?    |    Bob asked ... Charger fault?    |    Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Click here to ask your question

water is too hot?

my hot water is too hot.i have fitted a new cylinder stat and set it at 50 deg but the water is still too hot, the boiler is an ideal classic and was set at 77 deg(no5) but i have reduced it to 72deg(no4) .
mick kitcher, April 2009
Have you considered trying setting number 3?

It could solve your problem and save you money :)

Peccavi, April 2009
check immersion isnt switched also zone valve could be stuck open so its always heating the cylinder.

aa, April 2009
Hi,

Where did you mount the stat on the immersion? it should be 1/3 from the bottom. Is it wired the right way?

IrishFire, April 2009