Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Suzie asked ... Stuck Feed dog?    |    Click here to ask your question

baxi solo boiler will not start up?

pilot is lit, stat is calling for heat, programmer is callin g for heat but boiler will not start
wolstenholme, April 2009
if you look through the sight glass when you are asking the boiler to come on in heating or hot water mode does the pilot light if yes can you hear a continuious click click clicking noise whilst the pilot is lit if so it is the main ignition pc board if there is no flame during this ignition sequence it could be a blocked pilot or the solenoid on the gas valve is not opening to allow gas to the pilot if its dead completely with no pilot listen to see if the fan runs if you dont hear anything it may be the fan or air pressure switch

john patterson, April 2009
PROBABLY SOLENOID NOT OPENING(ASSUMING YOU'VE ELECTRICALLY CHECKED ROOM STAT AND PROGRAMMER ARE WORKING)

MC, April 2009