Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

How do I switch off my radiator?

It refuses to go off even when the thermostat is at "zero"?
Willis, April 2009
zone control is gone-stuck in the open position. temporary fix is remove the yellow wire and marrett off you will need to replace the valve before the next heat season.

P, April 2009
Are you Talking about a Thermostatic Radiator Valve?
if so
Remove the Head by unscrewing the lock nut below the temp sensor part, check that the pin in the Valve part is free to move up & down (use the head of a screwdriver to help)
If is free REPLACE THE TRV Head if availible or Complete Valve

Boiler Repairman - Ipswich, April 2009