Cam asked ... How can I fix my Bison 50 stairlift?    |    Alfred Briffa asked ... How to build a battery conversion adapter?    |    dunny asked ... Mute?    |    Chris asked ... Hotpoint FETC70P(UK) tumble dryer fault?    |    Debbie asked ... Kenmore 385.1695180 stitch selector/length/width/reverse?    |    Click here to ask your question

presure?

i have lost water presure due to a leek on 1 radiator,i have fixed the leak put cannot get presure back in the boiler
jason, April 2009
you should have a silver braided hose below your boiler with isolation valves either with a black lever or a screw head turn until you hear the water passing and the pressure rising then turn off when you reach about 1 1/2 bar if you dont have a boiler filling loop you may have an integral filling loop if so i need to no what boiler you have

STE, April 2009