andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

What's wrong with my Profile 50e boiler?

I've just bled all the radiators in my flat, and now my Profile 50e boiler has gone mad. The pilot light doesn't come on unless the thermostat on the boiler is set to max, and when it does come on it makes a frightening chugging noise with an intermittent "ping" sound. Does anyone know what's wrong with it? I've turned it off at the mains out of fear.
Dana, January 2006
hi,
hard to say without more info, but sounds like either an airlock, or lack of pressure in the radiator water system.
if you have a filling loop tap and guage then you need to top up the pressure on the guage to about 1.5.
if you have a loft tank then it is possible the ballvalve has stuck and needs to be freed.
if these things are too hard foryou to work out then unfortunately you need a heating engineer...unlikely to be the boiler at fault

graham, January 2006