Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Suzie asked ... Stuck Feed dog?    |    Click here to ask your question

Vokera 80 SP?

Hi, when my heating is on and the thermostat is calling for heat the boiler comes on but every say 15-30 seconds the gas valve keeps shutting off and re-igniting. Is this a fault on the pressure differential switch i.e. the diaphram is shot or gas valve solenoid? Or some other fault?
Your help would be appreciated.
Regards
David.
David Olliver, May 2009
Classic flue venturi problem that this and similar models suffer, google it. You are meant to get a corgi man to attend to it, or (if it is your own boiler in your house) be a 'competent person', as the flue Venturi is part of the safety system and is inside the sealed chamber.

You can diagnose it without opening the sealed chamber by looking for the air switch dropping out when the fan is on full, you need a multimeter an earth leakage breaker and great care that you dont electrocute yourself as there are mains voltages. The wiring schematic is in the back of the downloadable manual. The venturi needs to be spotless to work, build ups of grime or corrosion on its surface stop it working. Best left to a corgi man who knows this model and its typical faults well.

c, May 2009
Could be one of several causes best to get a Gas Safe Register Engineer in to have a look and diagnose the fault it will be cheaper in the long run

www.elanar.co.uk, May 2009
could be the flame detector

b, May 2009