Andrew - C asked ... Stannah 400?    |    Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    Click here to ask your question

Why do the upstairs radiators come on when i run the bath?

I have a Glow-worm 38cxi combi boiler. Just recently the hot water runs just warm even if it is turned to maximum. Also the upstairs radiators come on when i run the bath. The boiler is only 3 years old.
Ken, May 2009
This diagram...

http://www.diyfaq.org.uk/plumbing/combi.html

shows the paths for hot water and heating - if the diverter valve is in the wrong position (stuck half way) the heat output might be shared between rads & taps even though it should all go to the taps.

I would suspect the diverter valve being defective and causing your problem.

Peccavi, May 2009