Mike asked ... Bosch WTA74200GB Vented Dryer?    |    Stuart G asked ... C3 Front Wiper control problem?    |    Clare S asked ... Repair Electriq dehumidifier?    |    Bob asked ... Charger fault?    |    Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Click here to ask your question

worcester 24i combi , overflow leaking , pressure to 3 bar , ?

just replaced water feed and another part which started to leak after i had blown the system of water, i think this was the ball valve,this is the 2nd time in a month , whats else could it be ?, thanks
northener, May 2009
Overflow will run at 3-00 Bar pressure, this should be reduced to 1-00 Bar, make sure the filling loop is completely turned off afterwards, you could have a problem with the expansion vessel, if the pressure rises and falls significantly

www.elanar.co.uk, May 2009