Katie Bond asked ... Fixing auto threader on Baby Lock Enlighten Overlocker?    |    Chris. asked ... Miele W800 novotronic washing machine?    |    Larry asked ... How to stop my steam iron from leaking. Model dw2463 Rowenta?    |    HT asked ... Radio code Philips 22RC200/35?    |    Roberta asked ... DW5080?    |    Click here to ask your question

Ideal Standard valve assembly replacement?

I have a dual button flush Ideal Standard cistern and the water doesn't shut off when the float reached the top of its travel. Even lifting it manually the water still comes in. How do I remove the complete assembly?
Alan, June 2009
If it's the float ball and arm type you don't have to replace. Turn off the water to the cistern Remove the float arm, Usually held by a pin, remove the large knurled nut and plunger on the valve assembly the large washer is what that plunger pushes against to shut water off and its likely the washer has 'holed' replace this washer re-assemble the arm turn on water job done. If it over fills re-adjust the rod that pushes against the plunger.