Suzanne asked ... Washing programme stops after 3 minutes?    |    Rif asked ... Kenwood Dishwasher KID60S20 leaking from front?    |    Fraser asked ... Spares for power craft ppcs 38cc?    |    FB asked ... Toyota Yaris Speed Camera Warning Beep?    |    Ela asked ... Worcester 30 Cadillac combi boiler won’t fire up and the EA?    |    Click here to ask your question

feroli boiler D.H.W?

my boiler would not give hot water so i fitted a new dom hot water sensor i can now get hot water but i have to juggle with hot tap to turn the flow down to get hot water once its struck up it seems o.k.
its a ferroli optama 701 about 6 yrs old
peter.s., July 2009
think ive found the problem ,the flow meter was asembled the wrong way round, the flow restricter was asembled on the inlet side with the filter and the small O ring had come adrift inside the flow meter and jaming the wheel. Thanks "ferroli eng"

peter.s., July 2009
were about would this diafram be located or is it the flowmeter that just wants cleaning

peter.s., July 2009
its more than likely the flow switch as this causes the boiler to fire up in hot water to begin with take it apart and clean the components

ferroli eng, July 2009
how you going to change the diaphragm on this boiler it don't have a diverter valve.

hi-spec plumbing & heating (essex), July 2009
Hot water Diaphragm - fit a new one!
Should be done by a RGI, (Registered Gas Installer)

www.elanar.co.uk, July 2009