GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

new control for back boiler ?

i have just got a new timer for my baxi back boiler

its british gas emp2

its got a plug on the back whish says remove link if fitted for a pump system .

dont know weater to remove this plug or not
mark coleman, July 2009
It means if you have a fully pumped or a gravity hot water system. You should be able to tell if you have a gravity system by the looking at the pipes coming off of the back boiler, if there are only 2 then you have a fully pumped system, if 4 then probaly gravity. The other way to tell is if with your old timer you could have h/w only or c/h & h/w. Then it's prob gravity. If you can have c/h on it's own then it's fully pumped.

Ian, July 2009