Bob asked ... Charger fault?    |    Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    Click here to ask your question

HOW DO I FIX MY COMBI BOILER?

I have a VAILLANT 242 eh combi boiler installed, and is approx 12 years old. Water and heating working But pressure keeps dropping I fill the loop on a daily basis sometimes more regular I have re filled the expansion vessel to the VAILLANT specs, I have checked for leaks and can't find any. I have spoken to a plumber about It and all he could come up with was i need a new expansion vessel, he would not advise me on how to do the job, so i would appreciate any advice you can give me.
ARTHUR ROBERTS, July 2009
i have a eletric copper boiler for my hot water. it is not heating up how do i fix the element or reconent the wire.

rebecca wise, November 2009
my combi boiler was on the water setting instead of radiators and all of a sudden my heating came on.i always have it on just the water and flick it across when i need heating.this has never happened before.do you know why it would do that and how i can sort the problem out.thanks

tracy, July 2009
Look for leak on the pipe from the Pressure Relief Valve, this is the 15mm or 22mm copper pipe on your outside wall. Also if expansion vessel is in need of recharge you will see pressure on gauge ramp up quickly when you run boiler on central heating.
Expansion vessel needs to be recharged with boiler at zero pressure, ie close both flow and return isolation valves, open up the drain cocks( 10mm spanner) then check recharge vessel.

Andy, July 2009
The pressure vessel is split into 2 parts, 1 being the air side and the other being the water side from the boiler. The 2 parts are held apart by a rubber diaphragm which distorts, compressing the air side when the boiler is hot. Your system is losing water from somewhere, its as simple as that. The problem is, finding the leak! If its from the expansion vessel it should be obvious.

John, July 2009