GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

potterton puma, how can i rectify problem?

i've got a potterton puma 80 e boiler that does not light up when the hot tap or the heating goes on. the pilot ligth is constantly on but there is no fire from the main burner. i presume it could be a gas distrbution problem from the valve where it is monitored from. am i right or wrong
norris, February 2006
check the gas control knob that sticks through the panel is set to flame and not spark. Check to see if fan starts and then pump. This boiler has a common fault with the top left of main pcb. The input live/neutral and earth often arc on the metal casing. back of pcb.

richard, February 2006
link Click here to see other fixes for Potterton.