Morne asked ... My defy dtl 125 toploader?    |    Ernie asked ... How to fix gearchange ldv maxus van 2006?    |    Cuckoo asked ... Changing batteries on a fixed bt corded phone?    |    Marc Nollid asked ... Nissan Micra mk 5 2018 rear seat mecanism?    |    Maggie asked ... New Home 535?    |    Click here to ask your question

worcester 28 cdi boiler?

the pressure gage is at max 4 bars,i bled the radiators,and replaced the loop,but the pressure keeps rising to max,what else can i do ...thanks
terry, August 2009
how do i re-presurise by expansion vessel and to what pressure ?? thks

wayne, September 2009
did you manage to resolve the problem? If so, what did you do as this is happening to my boiler?

dg, September 2009
no db thats only if you get a excessive rise when system hot ie using the heating.

max rise even when cold is like mentioned below...plate exchanger

a, August 2009
had this problem myself it was the expansion vessel needed pumping up this solved mine

db, August 2009
Disconnect the Filling Loop to prove that it is not letting by, if pressure continues to rise then the Hot Water Plate Heat Exchanger is probably to blame

www.elanar.co.uk, August 2009