Morne asked ... My defy dtl 125 toploader?    |    Ernie asked ... How to fix gearchange ldv maxus van 2006?    |    Cuckoo asked ... Changing batteries on a fixed bt corded phone?    |    Marc Nollid asked ... Nissan Micra mk 5 2018 rear seat mecanism?    |    Maggie asked ... New Home 535?    |    Click here to ask your question

Problem with Worcester 24CDI combi boiler?

This combi is now 7 or 8 years old and has given good service, the overflow pipe which is vented external to the house has dripped for some time. Now the drip of water has increased to several litres a day. Has anyone got any ideas.
Mervyn Holland, August 2009
if filling key is not in place,then cold mains pressure is being fed into heating via plated heat exchanger.drop pressure of combi ,if pressure rises on its own then new domestic hot water plated heat exchanger is requred

billy, September 2009
you need your expansion vessel re-pressurised and the pressure relief valve replaced. check that the filling loop is properly closed.